11
5-3. Frequency Charts
Indoor unit SAP-KRV91EH
Outdoor unit SAP-CRV91EH
1) Rating conditions in cooling mode are:
Indoor: 27°C D.B. / 19°C W.B.
Outdoor: 35°C D.B. / 24°C W.B.
2) Fan speed: High
NOTE
230V Single Phase 50Hz
0
200
400
600
800
1000
1200
1400
0102030405060708090
Operating Freqency (Hz)
Power Input (W)
54
700
Cooling
Power input (W)
Operating frequency (Hz)
0
1
2
3
4
5
0102030405060708090
Operating Freqency (Hz)
Cooling Capacity (kW)
54
2.8
Cooling capacity (kW)
Operating frequency (Hz)