9-1-4. Frequency Control
During Automatic Operation, temperature and fan speed are adjusted according to the room conditions to keep
the room comfortable.
< Dry Operation >
Dry operation is as described in the diagram
at right.
If the room temperature drops below 15°C,
the unit operates under monitored status.
Within the monitored area, the air condition-
er does not operate but the operation lamp
remains on.
The compressor operates with 1/f fan operation. Also, the indoor fan operates under 1/f mode while the compres-
sor is running.
The compressor operates with 1/f fan operation with lower operation frequency than Dry AA. The indoor fan oper-
ates under 1/f mode while the compressor is running.
The compressor repeats a cycle of ON for 3 minutes and OFF for 6 minutes.
The indoor fan operates under 1/f mode while the compressor is running.
If the compressor is turned OFF and the room temperature falls below approximately 20°C, the
indoor fan also will be turned OFF.
9-1-5. HA Operation Mode (JEMA)
When the operation is started by HA, it is switched to Automatic Operation mode.
When the operation mode is changed by the remote control unit during the operation, the previous operation
mode is selected in the following operation.
One cycle of HA Terminals 1 – 2 consists of short – open of input pins for operation / stop.
9-1-6. Lamp Colors
Operation Lamp
Heating Operation ................(red) Dry Operation.............(orange)
Cooling Operation ................(green) Air Cleaning................(green)
Timer ....................................(green) Filter ...........................(orange, red)
People Sensor Lamp............(green)
9-1-7. ON Timer
The air conditioner starts operation at the preset time.
ON timer can be set / canceled while the air conditioner is not operating. When the timer is set, the timer lamp
on the main unit illuminates.
9-1-8. OFF Timer
The air conditioner stops operation at the preset time.
OFF timer can be set / canceled while the air conditioner is operating. When the timer is set, the timer lamp on
the main unit illuminates.
NOTE
NOTE
Load
< Cooling Zone >
< A Zone >
< AA Zone >
< B Zone >
Thermo-OFF
point
When room temperature is below
15°C, always in the monitored area.
When temperature
of indoor heat exchanger
is below approx. 2°C,
the compressor stops
and freeze prevention
function is activated. The
indoor fan also stops.
Dry AA
Dry A
Dry B