9-1-9. Timer Back-up
If the indoor unit does not receive a time-up signal from the remote control unit at the preset ON / OFF time,
time-up is carried out by the back-up timer of the indoor unit within 15 minutes.
When the operation is started by using ON timer, and the air conditioner is not manually manipulated for 25
hours or more, then the operation is canceled automatically.
9-1-10. One-touch Eco
For environmental protection and energy savings, “One-touch Eco” sets the temperature to 28°C for Cooling
Operation, and to 20°C for Heating Operation, considered to be the recommended temperatures for cost effi-
ciency. This mode carries out economical operation by somewhat lowering performance. If it does not meet
your comfort needs, set instead to normal operation.
One-touch Eco can be set together with any other operation such as 1H timer or Night Setback operation, and
Eco setting has priority over other settings. (However, when Eco is used together with Night Setback opera-
tion, if the setting of these overlaps, then Night Setback setting prevails.)
During One-touch Eco, temperature and amperage settings cannot be altered.
9-1-11. Multi-sensor Control
This is performed during Heating, Dry or Cooling Operation. However it is not applicable to Air Cleaning
Operation.
Multi-sensor control is performed in combination with multi-room temperature control and multi-air flow control.
Set temperature is adjusted by using the difference between the temperatures detected by the remote control
unit and People Sensor remote control unit, in order to adjust the temperature of the entire room to make it
comfortable.
Judging temperature difference
Type of swing and sweep is selected by comparing the difference between the effective temperature detected
by the remote control unit and People Sensor remote control unit, and the temperatures detected 10 minutes
previously.
Left/right flap, up/down flap and fan speed are controlled by monitoring the movement of the temperatures
detected by the remote control unit and People Sensor remote control unit, in order to achieve uniform room
temperature distribution.
Type of horizontal sweep
Multi-temperature Control
Multi-air Flow Control
Left 100% Right 0%
Installation position
Right Center Left
Switching position
Horizontal sweep angle 40 – 100% 0 – 100% 0 – 60%
Even temp-distribution Mid-speed Mid-speed Mid-speed
* Stop for 30 seconds at 100% Nonstop * Stop for 30 seconds at 0%
Right High-speed High-speed High-speed
Emphasis on left Left Low-speed Low-speed Low-speed
* Stop for 30 seconds at 100% Nonstop Nonstop
Right Low-speed Low-speed Low-speed
Emphasis on right Left High-speed High-speed High-speed
Nonstop Nonstop * Stop for 30 seconds at 0%
* Heating Operation only.