Data Output
Your LA Reference balance is equipped
with an interface port for connecting
your choice of the following:
Printer
Peripheral device (e.g., computer)
Universal remote control switch
Printer
You can configure the print functions
to meet your individual requirements by
selecting the corresponding
menu code.
You can have printouts generated auto-
matically, or by pressing r; depend-
ent on or independent of the stability or
time parameters; with or without IDs;
and as standard or ISO/GLP-compliant
printouts.
ISO: International Organization for
Standardization
GLP: Good Laboratory Practice
See the section on “Data Output
Functions” in the chapter entitled
“Operation” for a detailed description
of data output options.
Interface Port
Instead of a printer, you may choose to
connect a different peripheral device,
e.g. a computer (PC). With an on-line
PC you can control both the weighing
cell and the display unit of the
LA Reference balance.
Request messages are sent via the inter-
face to initiate functions in the weigh-
ing cell and in the display unit. Some of
the functions generate response mes-
sages.
See the chapter entitled “Operation”
under the section on “Data Output” for
a detailed description of the interface
port.
Error Codes
If you press a key that has no function,
or which is blocked at a certain point in
an application program, this error is
indicated as follows:
a double-beep is sounded as an
acoustic signal if the key has no
function
a double-beep is sounded and a
mes-
sage is displayed for 2 seconds
in the
text line if the key function is not avail-
able at that time
The response to an operator error
is identical in all models of the
LA Reference series. See the chapter
entitled “Error Codes” for a detailed
description.
Storing Settings
Storing Parameter Settings
The settings configured are stored
in the balance’s non-volatile memory.
The most recent parameter settings are
active when you switch on the balance.
Saving Parameter Settings
You can assign passwords in order to
block access to:
Weighing parameters
Device parameters
Application parameters
Factory settings