Preparation
§ Switch on the scale: Press e
§ While all segments are lit,
press the ) key
§ Select the Application menu: Press k
repeatedly until
Appl is displayed
§ Open the Application menu:
Press the ) key
§ Select the Totalizing application:
Press the k key repeatedly until
the desired menu item is displayed and
press ) to open the submenu
Application Parameters: Totalizing
3.6. Minimum Load for Automatic
Storage/Transfer of Values
3.6.1* 1 digit
3.6.2 2 digits
3.6.3 5 digits
3.6.4 10 digits
3.6.5 20 digits
3.6.6 50 digits
3.6.7 100 digits
3.6.8 200 digits
3.6.9 500 digits
3.6.10 1000 digits
3.16. Automatic Storage
3.16.1* Off
3.16.2 On
3.17. Automatic Individual or
Component Printout when
Value Stored
3.17.1 Off
3.17.2* Generate printout
with complete standard
configuration each time
O is pressed
3.17.3 Generate printout with
complete standard con-
figuration only once
when O is pressed
3.22. Source of Data for Values Saved
Automatically
3.22.1* Application 1
3.22.2 Application 2
3.23. Value(s) to be Saved
3.23.1* Net
3.23.2 Calculated
3.23.3 Net and calculated
* = Factory setting
§ Press ) to save your settings
and press ( (repeatedly) to exit the
operating menu.
Minimum Load
The minimum load required for automatic
taring of the container weight on the
platform (“autotare first weight”) is config-
ured in the operating menu, under:
Appl: m.weigh: 3.5.
The minimum amount that a component
must weigh before it can be saved in
totalizing memory is configured in the
operating menu, under:
Appl 3:
totaliz: 3.6.
You can choose from the following
10 levels for this setting:
1 digit
2 digits
5 digits
10 digits
20 digits
50 digits
100 digits
200 digits
500 digits
1000 digits
The “digits” here refer to the scale intervals
in the connected weighing platform. If the
interval of the connected platform is 1 g,
for example, and 1000 digits are required,
you must place at least 1000 g (=1000
intervals =1000 digits) on the weighing
platform for autotaring (only with the
“Autotare first weight” option selected).
Data Record or Printout
In the operating menu, under:
Appl 3:
totaliz: 3.17.
you can configure whether a printout
is generated manually, by pressing p,
or automatically when a weight value
is saved in the totalizing memory.
If you select
3.17.1 for this setting,
printouts can be generated only manually,
by pressing p (individual printout).
If you select
3.17.2 (printout of a compo-
nent on request), the full printout is gener-
ated every time the “Print” key is pressed.
The total data record is printed when you
clear the totalizing memory (by pressing
the c key).
Application 3: Totalizing L