Averaging (Animal Weighing) Application V
58
Example:
Measuring 25 m of electrical cable.
Settings (different from the factory settings):
Setup: Application 1: Neutral measurement
Setup: Printout; PRTPROT 7.6.
then select the menu line items of your choice
1.) Place empty container on the
platform
)
2.) Tare the scale
Note: If the automatic tare
function is enabled, you do
not need to press the ) key
to tare the platform; the tare
weight is saved automatically
when you place the container
on the platform
248
3.) Signum
®
3 only:
Enter the weight of 1 meter of
cable using the keypad
(in this example, 248 g)
O
4.) Save the value entered as the
reference weight
5.) Place the desired amount of
cable in the container
Read the result
p
6.) Print the results
nRef + 1 o Configured printout:
wRef + 0.248 kg see page 81
G# + 6.794 kg
T + 0.541 kg
N + 6.253 kg
Qnt 25 o
--------------------