14 MICRA SATEL
TCP/IP – communication with the use of GPRS technology.
11 - present voltage at the output of built-in power supply (in the event of AC power loss
this is the voltage supplied from battery).
12 - status information about:
Z1...Z4 and TMP – hardwired zones. Depending on the operating mode, the colors
convey the following information:
communication device:
green – zone in normal state;
blue – zone bypassed (blocked);
red – digital zone violated / voltage has exceeded the value preset for threshold
H of analog zone,
orange – voltage has dropped below the value preset for threshold L of analog
zone,
gray – zone not used.
alarm device:
green – zone in normal state;
blue – zone bypassed (blocked);
light-green – zone violated;
red – alarm;
burgundy – alarm memory;
gray – zone not used.
Z6...Z13 – wireless zones. Depending on the operating mode, the colors convey
the following information:
communication device:
green – zone in normal state;
blue – zone bypassed (blocked);
red – zone violated
orange – zone tamper;
gray – zone not used.
alarm device:
green – zone in normal state;
blue – zone bypassed (blocked);
light-green – zone violated;
orange – zone tamper;
red – alarm;
burgundy – alarm memory;
gray – zone not used.
A bar indicating the level of communication between detector and module appears
under each wireless zone. The bar color provides the following information:
red – no transmission from the detector for 30 minutes.
green – quality of communication between detector and module. The bar length
illustrates the number shown in parentheses in the particular zone field,
"Presence check" column, "Options, zones, outputs" tab. The shorter the bar
and the lower the number in parentheses, the lower the communication quality.
NO1-NO1 and NO2-NO2 – relay outputs:
green – output inactive;
red – output active.