30 MICRA SATEL
Add input voltage value to message – option available for the communication device
mode. If the option is enabled, information on the current voltage value at the zone input
will be added to the SMS message about the analog zone status.
Fig. 13. „CLIP/SMS messaging” tab for the alarm device mode.
4.3.6 „REPORTING” TAB
Set CID codes automatically – option available for the alarm device mode. If the option is
enabled, the program will automatically select Contact ID codes for:
– events from the zones of 0. INSTANT, 1. 24H, 2. ARM/DISARM (SWITCH), 3. ARM/DISARM
(BUTTON) and 4. DELAY type;
– troubles, module related events (settings restart, clock programming) and SMS control;
– arming/disarming, alarm clearing and panic alarm triggering by using a keyfob (the
codes of these events can be programmed in the "Keyfobs" tab).
Note: With the "Set CID codes automatically" option enabled, entering the event codes
manually will be unavailable.