SATEL MICRA 37
Read – button enables data reading from the module.
4.4 PROGRAMMING WITH THE USE OF SMS MESSAGES
The module can be programmed using SMS messages:
• at any moment from the telephone whose number is programmed in the "Telephone
numbers for messaging and test transmissions" list, "GSM telephone, Monitoring stations"
tab;
• for 15 minutes after starting (restarting) the module from any telephone. On receiving the
SMS message intended for programming, the programming mode will be each time
prolonged by 15 minutes, running from the moment the message is received.
Using the SMS message you can:
1. Add telephone numbers to the "Telephone numbers for messaging and test transmissions"
list ("GSM telephone, Monitoring stations" tab, GPRS-Soft program), sending:
„SET1=+48XXXXXXXXX=” – adds T1 telephone number,
„SET2=+48XXXXXXXXX=” – adds T2 telephone number,
„SET3=+48XXXXXXXXX=” – adds T3 telephone number,
„SET4=+48XXXXXXXXX=” – adds T4 telephone number,
where XXXXXXXXX denotes the digits of the telephone number being added.
2. Delete telephone numbers from the "Telephone numbers for messaging and test
transmissions" list, sending:
„DEL1” – deletes T1 telephone number,
„DEL2” – deletes T2 telephone number,
„DEL3” – deletes T3 telephone number,
„DEL4” – deletes T4 telephone number.
3. Delete all telephone numbers from the "Telephone numbers for messaging and test
transmissions" list, sending "DELALL".
4. Reset the number of transmissions sent by the module, sending "RESET" (see: "Limit
number of notifications to" parameter, "GSM telephone, Monitoring stations" tab,
GPRS-Soft program). Having received such a message, the module will start counting
anew the transmissions sent.
5. Set time in the module from the telephone, sending "TIME".
6. Start the test mode, sending "TESTON".
7. End the test mode, sending "TESTOFF".
Note: As the module distinguishes between upper and lower case letters, the content of
SMS messages intended to program its settings should be entered with upper-case
letters.
4.5 CONFIGURING THE MODULE TO WORK IN ALARM DEVICE MODE
1. Click the "Options, zones, outputs" tab and then:
– enable the "Alarm device" option;
– define the wired zone parameters (wiring type, sensitivity, restore and zone type),
register and configure the wireless detectors (zone type, presence check option);
– if delayed zones are used, define the entry delay time;
– if the exit delay countdown is to run, allowing you to leave the premises without
triggering alarm, define the suitable parameter;
– define the output parameters (output type, cut-off time);