Unit 4: Standard Command Codes
SATO GL4xxe SBPL Programming Reference Page 4-39
POSTNET
FUNCTION
To print Postnet bar codes.
FORMAT
<ESC>BPn...n
n...n = 5 digits (Postnet-32 format)
6 digits (Postnet-37 format)
9 digits (Postnet-52 format)
11 digits (Postnet-62, Delivery Point format)
Place immediately preceding the data to be encoded.
EXAMPLE
<ESC>A
<ESC>H0100<ESC>V0120<ESC>BP94089
<ESC>H0100<ESC>V0160<ESC>BP123456
<ESC>H0100<ESC>V0200<ESC>BP123456789
<ESC>H0100<ESC>V0240<ESC>BP12345678901
<ESC>Q1
<ESC>Z
OUTPUT
(4-27)
NOTES
If the number of data digits does not match those listed, the command is ignored.
Only numeric data will be accepted.