Unit 4: Standard Command Codes
SATO GL4xxe SBPL Programming Reference Page 4-2
CONTROL COMMANDS
START/STOP LABEL
FUNCTION
For all print jobs, the Start command must precede the data and the Stop command
must follow. The print job will not run properly if these are not in place.
FORMAT
Start Command: <ESC>A
Stop Command: <ESC>Z
<ESC>A must precede data <ESC>Z must follow data.
EXAMPLE
<ESC>A
<ESC>H0001<ESC>V0100<ESC>WB1SATO
<ESC>H0130<ESC>V0200<ESC>B103150*SATO*
<ESC>H0170<ESC>V0360<ESC>L0202<ESC>S*SATO*
<ESC>Q1
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
There is no output for these commands they are not accompanied by other label
printing commands. However, these commands must precede and follow each print
job sent to the printer.