The hose lines have to be installed free of tension and untwisted.
Drainage
Correct
Incorrect
Note!
Accumulated ’condensate’ contains oil. It may only be disposed
of in compliance with applicable legal regulations.
J.P. SAUER & SOHN offers oill / water preparation systems for
separating the oil from the condensate.
Note!
We recommend to connect the compressor’s drainage separa-
tely.
When the drain lines of several compressors are to be connec-
ted to a common pipe, observe the following:
Choose a sufficient nominal diameter for the common drain
line;
Connect drain lines of the individual compressors at a sharp
angle to the common drain line, so no pressure can build up
in the drain line of a stopped compressor.
Correct
Incorrect