Factory Default settings / Options
2, 4, 6, ..............1200
Initial Impedance Set Up for ㏈m measurement
Impedance to measure ㏈m can be set up within the range of 1 ~ 1200Ω.
Factory preset value is 600 Ω.
Be
ep(Buzzer) Sound Set Up
This mode controls the sound during Continuity Test.
This mode can is set to ON or OFF in the User Menu.
[T
he WARNING sounds for input Over Voltage or battery power low warnings are set up with
the "TONE" setting which is a different set up procedure than the above Continuity sound.]
Key Sound(MUTE)
This mode toggles the Function key sound when Pressing “Function” keys.
This mode can is set to ON or OFF in the User Menu.
Auto Power Off
U
ser can select the APO(Auto Power Off) time in the range from 10minute~60 minutes
User can select 10, 15, 20, 30, 45, 60min, or OFF.
With the APO timer active, the Meter will be automatically Powered off after the set amount
of time unless any of following events occur.
Pressing any function key or menu key.
Change of measurement function.
Data Logging is Active
Peak Hold is Active
APO is disabled in the User Menu.
To turn the meter on from APO after Power is Off, press any key on the meter.
To disable APO function, select OFF in the User Menu.