Operation
26 01.00 | FPS-F5 | Assembly and Operating Manual | en | 15959911
6.2.3.3 Connect electronic processor to computer and remote
maintenance computer via the Internet
n Ports 5000-5002 are enabled
n The computer is connected to the electronic processor and the
Gateway and FPS-Controller programs are
installed, }6.2.3.2 [/25]
1. Open the DOS window in the computer.
2. Enter the command ipconfig and confirm by pressing Enter.
IMPORTANT!The IP address is also displayed via the
routeprint command.
ð IP address is displayed.
3. Close the DOS window.
4. Start the remote maintenance computer.
5. Start FPS Controller.
ð A login window appears, }6.3.2 [/29].
6. Enter password if required.
7. Select the network, enter the IP address of the computer
connected to the electronic processor and press OK.
ð The program window opens and the Programming
function is displayed, }6.3.3 [/29].
6.2.3.4 Connect electronic processor to modem and remote maintenance
computer via the telephone network
A communication program such as Hyperterminal is required to
connect the electronic processor to a modem and to access it
with a remote maintenance computer via the telephone
network.
1. In the communication program, select the Direct connection
via Com1 connection and enter the following parameters:
ð Bits per second: 9600
ð Data bits: 8
ð Parity: none
ð Stop bits: 1
ð Protocol: none
ð Press "OK"
2. Initialize modem to factory settings at &f --> Enter.
3. Initialize the modem with the following five commands.
ð The modem must respond to all commands with OK.