Assembly
210.00 | PZN-plus | Assembly and Operating Manual | en | 389374 35
5.3.9 Mounting programmable magnetic switch MMS 22-PI1
CAUTION
Risk of damage to the sensor during assembly!
l
Observe the maximal tightening torque.
NOTE
The magnetic switch MMS 22-PI1 can be adjusted and taught in
two ways.
l
"Standard mode" allows for quick installation on the T-nut
preset by SCHUNK in the groove or the defined setting
dimension "l1."
l
In "Optimal Mode", the sensor identifies the optimal position
in the groove itself.
SCHUNK recommends "Optimal Mode" for setting the sensors.
Setting the sensor in "Optimum mode"
1. Put product in the position in which it is to be set.
2. Hold teaching tool to the sensor1(1) until the sensor flashes.
3. Slide sensor1(1) into the groove(2), until the sensor1 flashes
rapidly.
ð The optimum position is displayed.
4. Secure the sensor1(1) using the set-screw(3).
Tightening torque: 10Ncm
5. Hold teaching tool to the sensor1(1) to confirm the position.
ð The sensor1(1) has been taught in.
6. Repeat steps for sensor2.

Table of Contents

Other manuals for SCHUNK PLZ Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCHUNK PLZ Plus Series and is the answer not in the manual?

SCHUNK PLZ Plus Series Specifications

General IconGeneral
BrandSCHUNK
ModelPLZ Plus Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals