EasyManuals Logo

SCHUNK PLZ Plus Series User Manual

Default Icon
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Assembly
210.00 | PZN-plus | Assembly and Operating Manual | en | 389374 47
5. Tighten screw (4) slightly.
6. Turn the screw (5) to push the position of the control cam (6).
7. Tighten screw (4) and in doing so press the control cam (6) in
the direction of the gripper finger.
8. Slide the sensor (1) to the stop into the bracket (2).
9. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
10. Adjust sensor (1), see assembly and operating manual of the
sensor.
Variant Dust-tight:
Screw in set-screw into the side cover.
5.3.16 Mounting the radio system RSS-R1/T2
The radio system RSS-R1/T2 can be used with the following
sensors:
l
Reed switch RMS 80
Assembly
1. Install the sensor, }5.3.13 [/43].
2. Adjust the sensor, see the assembly and operating manual for
the sensor.
3. Connect the radio system, see the assembly and operating
manual for the radio system.

Table of Contents

Other manuals for SCHUNK PLZ Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCHUNK PLZ Plus Series and is the answer not in the manual?

SCHUNK PLZ Plus Series Specifications

General IconGeneral
BrandSCHUNK
ModelPLZ Plus Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals