EasyManua.ls Logo

SCHUNK STM 48V - STM Overspeed; STM Oscillates; Bearing Noise

SCHUNK STM 48V
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
66 05/STM-48V/en/2011-04-01/CW
13.1.2 STM overspeed
Possible cause
Corrective action
Controller settings not ideal
Check the controller settings (direction of rotation of
motor and encoder direction of counting).
Insufficient power supply for the controller's
power component
Check the stability of the supply voltage. Use
transformers instead of a switching power supply
component.
Table 34
13.1.3 STM oscillates
Possible cause
Corrective action
Motor overload
Check the dimensioning
Reduce the load
Check the controller settings
Controller settings not ideal
Check the controller settings
Table 35
13.1.4 Bearing noise
Possible cause
Corrective action
Incorrect assembly
Check the evenness at the mounting surface (see
chapter 7.1, page 27)
Configuration incorrect
Check the parameters and setting values (see
operating manual for the controller).
Bearing defective due to overload
Send the module to SCHUNK with a repair order.
Table 36

Table of Contents