________________________________________________________________________________________________________________________________________Operating Modes
In this operating mode, any event appearance (alarm, fault, external command, ...) is signalled on screen. However, the generating set is
stopped and automatic start-up is not possible.
When the generating set is running and whatever the current mode (
Auto, TTest, MManu
), press the
Stop
button to stop it instantly without any cooling down. A message appears on screen for two seconds
to signal that the button has been taken into account (see screen opposite).
Note: if the engine is equipped with a water heater, the latter is not powered in
Stop
mode.
Ph./ph. U12
voltages U23
(Volts) U31
STOP mode selected
395
396
390
22..22.. MMaannuu MMooddee
The
Local
mode provides local control from the keyboard, ie, the operator is wholly in control of the start procedure.
-This mode may be accessed from the
Stop
or
AUTO
modes. Two alternative programmed solutions are available :
- 1 press on the key
- 2 presses on thse key
a) SSingle kkey ppress ::
The generator starts in
Local
mode after a single press on the
Local
key. Using this function:
- The red LED usually associated with the
Local
key does not flash,
- The message confirming the selection of
Local
mode does not appear.
b) DDual kkey ppresses ::
Pressing the
Local
key once, briefly, selects the mode and displays the screen below. The key's associated red LED also flashes.
Pressing the
Local
key, briefly, a second time confirms the mode selection. The red LED comes on permanently and the generator set then
enters its automatic start procedure phase (see paragraph 17).
Whilst the red LED is flashing (awaiting confirmation), the mode may still be changed by selecting
either
Stop
or
Auto
mode.
If the first pressure on the
Local
key is not confirmed within two minutes, one of two things may hap-
pen s:
-
Stop
mode will be selected automatically if this was the previous mode, or,
-
Auto
mode will be selected automatically if that were the previous mode.
In
Local
mode, switching between Normal and Emergency is enabled by pressing the 0 or 1 keys, but only if the green LED is ON (see
paragraph 18). The operator still has control over the Normal/EmergencyY switch and the generator set.
If an external Start command appears on the screen, the control unit remains in
Local
mode. The operator then has to change from the
Local
to
AUTO
mode.
Fuel Lev(%)
E.Speed(RPM)
Batt. (Volts)
MANU mode selected
press MANU to confirm
24
.
2
50
0
Fuel Lev(%)
E.Speed(RPM)
Batt. (Volts)
AUTO mode selected
24
.
2
50
0
Fuel
Lev(%)
E.Speed(RPM)
Batt. (Volts)
ext command=0 16:50
gen stand-by
12/01/00
24
.
2
50
0
From the waiting screen, the generating set start-up is conditioned by:
Logical status change of the 'external command' input
Logical status change of the 'EJP advance warning' or 'EJP start-up' inputs (France only)
Activation of the clock mode built into (if the mode is programmed).
Example: the right-hand side screen above informs of the logical status of the external start-up command (abbreviation ext
command=0
or
ext
command=1
):
- External command = 0, no start-up
- External command = 1, imminent start-up possible
When one of the three start-up conditions changes from 0 to 1 (for and ) or from inactive to active (for ), a new message informs
the operator, then the generating set enters into an automatic start-up phase (see paragraph 17).
When one of the three start-up conditions changes from 1 to 0 (for and ) or from active to inactive (for ), a new message informs
the operator, then the generating set enters into an automatic shutdown phase (see paragraph 17).
In
Auto
mode, the ATS toggle is completely automatic (see paragraph 18).
22..44.. TTeesstt MMooddee
Test
mode can only be accessed from
Auto
mode. If one of the inputs ; external command, EJP advance warning, EJP start-up, is in logical
status 1 or if the clock is active,
Test
mode cannot be selected.
If the inputs; external command, EJP advance warning, EJP start-up, are in logical status 0 or if the clock is inactive, press
Test
button to
select the mode and to bring up the screen below. The red LED associated with the button flashes.
22..33.. AAuuttoo MMooddee
Auto
mode can be accessed from
Stop
,
Manu
or
Test
mode. Press the
Auto
button to select the mode and to display the left-hand side screen
below for two seconds. The red LED associated with the button comes on, then the right-hand screen appears. This screen corresponds to
the standby state of the generating set.