Mass Flow Meter
Operation Manual
Standard: GB/T 31130-2014
Zhejiang System No. 03010003
Ver. V1.2

Questions and Answers

SeaLand Mass Flow Meter Specifications

General IconGeneral
TypeMass Flow Meter
Repeatability±0.2% of reading
Output Signal4-20 mA
Power Supply24 VDC
MaterialStainless Steel
Protection ClassIP65

Summary

Chapter 1 Specifications

1.2 Operating Principle

Explains how the mass flow meter measures flow based on Coriolis effect.

1.3 Features

Lists the key characteristics and advantages of the mass flow meter.

Chapter 2 Composition

2.1 Mass Flow Sensor

Details the mass flow sensor, its components, and main parameters.

2.2 Mass Flow Transmitter

Describes the mass flow transmitter, its main features, and dimensions.

Chapter 3 Installation

3.1 Installation Steps

Step-by-step guide for installing the mass flow meter correctly.

3.2 Installation Guidelines

Covers site selection, methods, grounding, and startup procedures for safe installation.

Chapter 4 Wiring

4.1 General Wiring

Overview of wiring options and requirements for transmitter power and signals.

4.2 Sensor to Transmitter Wiring

Details the 12-pin cable connections between the sensor and transmitter.

Chapter 5 Operation Interface

5.1 Operation Panel Overview

Identifies components of the transmitter's operation panel and indicators.

5.2 Display Interfaces

Explains the different display screens and their functions.

5.2.1 Main Interface 1

Describes the primary display screen for mass and volume flow rates.

5.2.2 Main Interface 2

Details the secondary display screen for density and temperature readings.

Chapter 6 Configuration Software

6.2 Meter to Computer Connection

Steps to connect the meter to a computer using a USB-to-RS485 converter.

6.3 Process Variable Monitoring

How to monitor real-time flow rate, total, density, and temperature via software.

6.6 Density Calibration

Instructions for density calibration when replacing the transmitter.

Chapter 7 Operation

7.1 Calibration Coefficient Setting

How to set or modify the calibration coefficient for accurate measurements.

7.2 Minimum Flow Cut-off

Configuration of the minimum flow rate to avoid inaccurate readings.

7.5 Zero Calibration Setting

Procedure for performing zero calibration to ensure accurate baseline readings.

7.10 Password Setting

How to change or set the password for accessing certain functions.

Chapter 8 Explosion-proof

Chapter 9 Troubleshooting

9.1 Self-Diagnosis

Using the software's self-diagnosis feature to identify potential errors.

9.2 Troubleshooting Guide

Common errors and their possible causes and solutions.

Chapter 10 Completeness

Chapter 11 Transport and Storage

Appendix 1 Function;Operation Table

Appendix 2 Abbreviation Explanation Table