TS Sync Loss: the MRD 5800 will switch
from the primary to the backup input if the
primary stream loses synchronization for the
duration of the Switchover Interval.
Decode Failure: the unit will switch to the
backup input when it encounters decoding
errors on the primary input.
Primary Input TS Restored
Backup Input TS Sync Loss
Decode Failure
Manual Only: the unit will not restore to the
primary input automatically. The user must
manually switch inputs.
Primary Input TS Restored: the MRD 5800
restores to primary when the Primary input
regains transport stream synchronization.
Backup Input TS Sync Loss: the unit will
switch from backup to primary when the
backup stream loses synchronization for the
duration of the Switchover interval.
Decode Failure: the unit restores to the
Primary Input when the Backup Input
experiences a decoding error.
The time in seconds which Switch On or
Restore On value must remain in the
configured state before the MRD 5800
switches between the Primary Input and
Backup Input or vice versa.
4.2.2 Configuring ASI Input
This menu allows the user to either Enable or Disable the ASI Input on the MRD 5800.
Beginning with revision J main boards the ASI ports can be configured as either an input
or output. Earlier revision remain configured as 1 input and 1 ouput port. Main board
version can be located on the About tab under the Options section.
Rev I and earlier main board ASI options