R301 RF POWER SUPPLY OPERATOR’S MANUAL
Response: <prompt><cr>
S Disable the RF Output
Command: S<cr>
Response: <prompt><cr>
W Set the Power Setpoint
Command: XXXX_W<cr>
Where XXXX is the desired setpoint, in 1-Watt increments, 1 to 4 digits.
Response: <prompt><cr>
V Set the Voltage Setpoint
Command: XXXX_V<cr>
Where XXXX is the desired Voltage setpoint, in 1-Volt increments, 1 to 4
digits.
Response: <prompt><cr>
D Set the Process Pulse Duty Cycle
Command: XXX_D<cr>
Where XXX is the process pulse duty cycle, 1% to 100%, in 1%
increments. 1 to 3 digits.
Response: <prompt><cr>
HT Set the Process Pulse high time
Command: XXXX_HT<cr>
Where XXXX is the process pulse high time, in milliseconds. 1 to 4
digits.
Response: <prompt><cr>
LP Set the Process Pulse Low Power Setpoint
Command: XXXX_LP<cr>
Where XXXX is the process pulse low power setpoint, in Watts. 1 to 4
digits.
Response: <prompt><cr>
HP Set the Process Pulse High Power Setpoint
Command: XXXX_HP<cr>
Where XXXX is the process pulse high power setpoint, in Watts. 1 to 4
digits.
Response: <prompt><cr>
ECHO Enable ECHO mode
Response to commands includes the <prompt> plus the command string
sent to the unit, terminated with <cr>.
Command: ECHO<cr>
Response: <prompt><cr>
Page 22
Seren IPS Inc.
6100130000 Rev. 0.05