32 User Functions Super II
7. Enter the weight value on the numeric keypad or by placing pieces to be counted on the weighing pan and press the LOW,
TARGET, or HIGH soft key to set the value for each register.
a) To enter a value different from the one displayed into the LOW, TARGET, or HIGH register, type in the
desired value using the numeric keypad followed by the soft key for the appropriate register.
b) You can have the scale automatically calculate the LOW and HIGH limits as a percent deviation from the displayed target
weight or count by typing in the allowable percent error using the numeric keypad followed by the % soft key.
8. For better viewing of the displayed weight or count along with its LOW, TARGET, and HIGH set points, press the EXIT
soft key to return to the default User Menu.