Digital Weighing Indicator
SI 4100
- 23 -
Display Up-date rate selection (per sec)
F13
●
0
238 times
1
102 times
2
64 times
3
47 times
4
34 times
5
31 times
6
26 times
7
23 times
8
20 times
9
18 times
Sp1, Sp2, Sp3, Sp4 Set value apply selection
F14
●
0
Apply only certain P/N
1
Apply same set value to all P/N
Auto TARE Reset time setting
F15
00
01
∫
99
Automatic “TARE” reset time setting.
00 : not use
30 : after 3.0sec, Tare will reset.
Minus(-) symbol display selection
F16
●
0
Display (-) symbol on the display
1
Not use
“NEAR ZERO” relay output mode selection
F17
●
0
Display weight is Zero Near Zero relay output
1
Only Gross Zero(Net weight + TARE) Near Zero relay output
Equipment No. setting
F18
01
01~
99
Equipment No. setting with No. key. (01 ~99 settable)
“Key Tare” selection
F19
●
0
Key Tare Not Use
1
Key Tare Use