Digital Weighing Indicator
SI 4100
Serial Communication Speed selection
DATA Transference Method selection
Simplex Mode / Stream Mode
Duplex Mode / Command Mode
Print port selection (Under F62-01 setting, only)
Same port as using for Command Mode.
“Check-Sum” detection selection (Under F62-01 setting, only)
Check-Sum data will not be included on transferred data.
Check-Sum data will be included on transferred data.
Serial Port Application Selection (Under F62-00 setting, only)
DATA Transference purpose
Printing purpose (Serial Printer)
DATA Transference Mode selection (Under F62-00, F65-00 setting, only)
Stream Mode : Weighing Data will be transferred continuously.
Finish Mode : When Finish Relay output, only 1 time transferred.
Manual Mode : When “Print” key input, 1 time transferred.
DATA Transference Format selection(Under F62-00, F65-00 setting, only)
Format 2. (Format 1 + ID No.)
Print Mode selection (Under F62-00, F65-01 setting, only)
Manual Print : Whenever “Print” key input.
Auto Print : When Finish relay output, automatically print.