AL-2041 SIMULATION, TROUBLE CODES 10 - 7
26 04 Machine duplex setup
(AL-2041 only)
[Function]
When this simulation is executed, the current set duplex is displayed. Enter the code number
corresponding to the desired duplex and press [START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
06 Destination setup [Function]
When this simulation is executed, the current set destination is displayed. Enter the code num-
ber corresponding to the desired destination and press [OK]/[START] key to save the setting.
* Code number 2 and 3 cannot be selected.
[Operation]
The operation is similar to simulation 26-02.
07 Machine conditions check [Function]
When this simulation is executed, the current machine setting is displayed.
20 Rear edge void setup [Function]
When this simulation is executed, the current set rear edge void is displayed. Enter the code
number corresponding to the desired rear edge void and press [START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
30 CE mark support control
ON/OFF
[Function]
When this simulation is executed, the current set CE mark support control is displayed. Enter
the code number corresponding to the desired CE mark support control and press [START] key
to save the setting.
[Operation]
The operation is similar to simulation 26-02.
38 Cancel of stop at drum life
over
[Function]
When this simulation is executed, the current setup of the code number is displayed. Enter the
code number and press the [START] key to enable the setup.
[Operation]
The operation is similar to simulation 26-02.
39 Memory capacity check [Function]
When the simulation is executed, the currently installed SDRAM of the main unit is displayed.
Main
code
Sub
code
Contents Details of function/operation
Code number Duplex
0 Duplex NO
1 Duplex YES
Code number Destination
0 Inch series
1 EX Japan AB series
2 Japan AB series
3 China
CPM Copy quantity Remark
20 CPM 20
Code number Setting Remark
0 Rear edge void NO
1 Rear edge void YES Default
Code number Setting Remark
0 CE mark support control OFF Default (100V series)
1 CE mark support control ON
Code number Setup
0 Stop at drum life over * Default (AL model)
1 Cancel of stop at drum life over
Code number Setting Remark
32 32 MBYTE