7) Remove the toner bottle. (See a. Toner bottle unit in [Toner
hopper and toner bottle section])
8) Remove the toner hopper unit. (See b. Toner hopper unit in
[Toner hopper and toner bottle section])
9) Remove the developing unit. (See a. Developing unit in the
[Developer tank section])
10) Remove the process unit. (See a. Process unit in the [OPC drum
section])
11) Raise the process DV cover diagonally, and remove the front right
cover.
12) Remove the front cabinet upper.
13) Remove the paper exit tray cabinet unit.
14) Remove the paper exit port cabinet, and remove the paper exit tray
cabinet C.
15) Disconnect the connector and remove the harness clamp. Remove
the main duct unit.
16) Remove the fan unit.
17) Disconnect the connector and remove the process exhaust fan
motor 1 (A), 2 (A), and 3 (C).
NOTE: When assembling, fit the mark with the fan rotating direction
(label on the back surface).