EasyManua.ls Logo

Sharp AR-M550N - Adjustment Mode Selection; Scan Off-Center Adjustment

Sharp AR-M550N
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AR-M550/M620/M700 SETTING AND ADJUSTMENTS 7 - 23
(Scan off-center adjustment)
1) Place an original on the original table.
2) Press the Start key
Check the off-center of the printed image.
If the off-center is 0±4.0 mm, no adjustment is required.
If the above requirement is not met, do the following steps.
3) Using the numeric keypad, change the adjustment value in steps
of 0.1 mm to adjust the scan image off-center. A larger setting
shifts the printed image toward the rear side.
4) Press the P or Start key.
Pressing the Start key starts copy operation as well as applying the
adjustment value.
5) Check the off-center of the printed image.
Repeat the above adjustments until an acceptable result is
obtained.
This adjustment is needed in the following situations:
The MFP control PWB has been replaced.
The EEPROM on the MFP control PWB has been replaced.
The scan control PWB has been replaced.
The EEPROM on the scan control PWB has been replaced.
The scanner (reading) section has been disassembled.
The scanner (reading) unit has been replaced.
U2 trouble has occurred.
The SPF section has been disassembled.
The SPF unit has been replaced.
(Adjustment mode selection)
1) Go through the modes specified in Simulation 50-12.
2) Using the numeric keypad, select the adjustment item SPF SIDE1,
which is intended to adjust the off-center in SPF front-face mode.
3) Press the Start key
ADJ 7C Adjust the scanned image off-center in
SPF front-face mode (scan section)
original copy
a
b
Select 2, and
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
Item Set range Default
0 TRAY SELECT Paper feed tray
selection
1 - 6
1 COPY START Copy START (Default) ––
2 MAGNIFICATION Print magnification ratio 25 - 400% 100
(Off-center adjustment value)
3 PLATEN OC mode adjustment 0 - 99 50
4 SPF SIDE1 SPF front surface
adjustment
5 SPF SIDE2 SPF back surface
adjustment
50
1
2
Select 1,
and press
[START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
Select 0, and press [START] key.
Press [START] key or
press [CUSTOM SETTINGS] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 0-9, AND PRESS
START.
0.TRAY SELECT 1 1.COPY START
2.MAGNIFICATION 100
(ADJUSTMENT DATA)
3.PLATEN 50 4.SPF SIDE1 50 5.SPF SIDE2 50
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. NOW COPYING.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. INPUT VALUE 0-99, AND
PRESS START.
3.PLATEN
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 1-16, AND PRESS
START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT 6.LCC
(ABOVE+10: DUPLEX MODE)
Select other than 0 - 2, and press [START] key.
100
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)

Table of Contents

Other manuals for Sharp AR-M550N

Related product manuals