MX-M700N SCANNER SECTION D – 5
7) Remove the tray.
8) Remove the left side cabinets front and rear.
9) Remove the screws.
10) Hold the both sides of the scanner base, and slide it toward
you to remove.
a. Table glass
b. White standard glass
(When scanner iinternal maintenance)
1) Loosen the screws in the hinge section, and lower the two
metal fixtures.
2) Open the DSPF, and slide the DSPF drop-preventing stopper
pin of the Hinge L to the drop preventing position.
3) Remove the right glass holder.
4) Using a cloth, etc. on the right glass surface to prevent finger-
prints, remove the cover.
5) Remove the white reference glass unit.
* When assembling or disassembling the table glass, check
that the glass does not cover the steel plate on the front
side.