13
The first five digits of the key are highlighted or underlined to help the user identify the PIN
Code part of the DSK text. The DSK is additionally represented with a QR Code as shown on the
image.
Z-Wave DSK label and QR code (example)
A joining node requesting to join the S2 Access Control Class or the S2 Authenticated Class will
obfuscate its Public Key by setting the bytes 1…2 to zeros (0x00) before transferring its key via
RF.
The DSK may be used for out-of-band (OOB) authentication.
The including gateway may use a QR code scanning device to read the entire DSK of the joining
device and match it with the obfuscated public key received via RF from the joining device.
NOTE: This Device must be used in conjunction with a Security Enabled Z-Wave gateway to
fully utilize all implemented functions.
NOTE: This Device is a security enabled Z-Wave Plus® product that can use encrypted
Z-Wave Plus® messages to communicate to other security enabled Z-Wave Plus® products.
NOTE: DSK access via UI gateways, which implement the S2 and SmartStart security feature,
display an input dialog box, with a full or partial DSK key. Most of them display a partial DSK
(they do not show the PIN code) when the Device is added with the S2-Authenticated security
scheme. When added with the S2-Unauthenticated, some gateways show the complete DSK
while others perform the complete adding (inclusion) process without prompting the user with
the dialogue.
9. LED Signalization
General rules
Switching between Normal and Settings mode is done by Single press on the S button
Solid LED means that you are in the Settings mode (this is not valid for Plugs). Ones in
settings mode, switch to normal mode goes automatically after 10s
If the LED is not in Alarm mode, it will turn off after a timeout of 30 min. Pressing the S
button or power cycling the Device will wake the LED for 30 min.
Normal mode LED status: Normal mode is defined by stable device function that can remain for
an infinite time.
LED type: RGB dimmable
Normal mode

Table of Contents