19
NOTIFICATION_EVENT_SMOKE_ALARM_SMOKE_DETECTED 0x01
NOTIFICATION_EVENT_SMOKE_ALARM_SMOKE_DETECTED_UNKNOWN_LOCATION
0x02
Values size: 4 Byte
Default value: 0
Values & descriptions:
0 no action
1 open relay
2 close relay
Parameter No. 93 - CO Alarm
This parameter determines how the device should respond to the reports of alarm frames. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
The notification types it reacts to are as followed:
Notification Type:
NOTIFICATION_TYPE_CO_ALARM 0x02
Notification Events:
All except ALARM_NO_EVENT 0x00
Values size: 4 Byte
Default value: 0
Values & descriptions:
0 no action
1 open relay
2 close relay
Parameter No. 94 - Heat Alarm