20
This parameter determines how the device should respond to the reports of alarm frames. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
The notification types it reacts to are as followed:
Notification Type:
• NOTIFICATION_TYPE_HEAT_ALARM 0x04
Notification Events:
• NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_RISE_LOCATION_PROVIDE
D 0x03
• NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_RISE 0x04
• NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_FALL_LOCATION_PROVID
ED 0x0C
• NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_FALL 0x0D
Values size: 4 Byte
Default value: 0
Values & descriptions:
• 0 no action
• 1 open relay
• 2 close relay
Parameter No. 105 - LED Signalisation intensity
In Wave 1, Wave 1PM and Wave 2PM, Plug US, Plug UK, this parameter will be implemented in
2024. This parameter determines the intensity of the LED on the Device. Some Devices have
RGB LEDs and some have Blue/Red LEDs, but all are dimmable.
Values size: 1 Byte
Default value: 100
Values & descriptions: 0-100 (0-100%, every 1%)
Parameter No. 120 - Factory Reset
Reset to factory default settings and removed from the Z-Wave network.