EasyManua.ls Logo

Shelly Wave 1 Mini - 12 Z-Wave Notifications Command Class

Shelly Wave 1 Mini
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Supporting Command Class Basic
COMMAND_CLASS_BASIC is mapped into COMMAND_CLASS_SWITCH_BINARY, for enabling
Switch (O) control:
Switch (O) will be turned ON or OFF, after receiving the BASIC_SET command:
Basic Command received
Mapped Command (binary Switch)
Basic Set (0xFF)
Switch Binary Switch (0xFF)
Basic Set (0x00)
Switch Binary Switch (0x00)
Basic GET
Basic Report (Current Value, Target Value)
Supporting Command Class Indicator
The Device supports the Command Class Indicator V3 (ID 0x50). When the Device receives an
indicator set, the LED blinks according to the received indicator set.
Refer to LED Signalization chapter.
12. Z-Wave Notifications Command class
Overheat detected
Comment
Overheat detected
Z-Wave Notification Type Name
Heat Alarm
Z-Wave Notification type - Value
0x04
Z-Wave Notification type - Event
State
Z-Wave Notification Name
Overheat detected
Z-Wave Notification Name - Value
0x02
Z-Wave Notification Name - Version
V2
LED signalisation
Check LED signalisation
table
Device reaction - Switch OFF all outputs and send notification
Yes
Action to restore - power cycle
Yes
Action to restore - short press on S button
Yes

Table of Contents