restart temperature are a –15 C] and –13 [°C] respectively, minimum admissible
values.
The minimum working temperature must be at least 2 C] lower than the restart
temperature.
Proceed as follows to set minimum working temperature:
o When the pump is in standby, see Paragraph 5.2.2, press and hold down
for 3 seconds.
Figure 15: Minimum working temperature and restart temperature.
o Regulate minimum working temperature with keys (increase),
(decrease). Minimum working temperature cannot be under –15 C] (-F),
the regulation interval for minimum working temperature is -15÷97 C].
o Press , to regulate the restart temperature.
o Regulate restart temperature with keys (increase), (decrease).
Minimum restart temperature cannot be under -13 C] (-d), the regulation
interval for restart temperature is -13÷99 [°C].
5.2.8. Automatic start settings.
When the pump is in standby, see Paragraph 5.2.2, press to turn on the
automatic start mode. Press (increase), (decrease) to select when the heat
pump should automatically start (1÷24 hours).
Figure 16: Automatic start settings.
Automatic start can only be set when the pump is in standby, see Paragraph 5.2.4.
5.2.9. Automatic standby settings.
When the pump is running, see Paragraph 5.2.4, press to turn on the automatic
standby mode. Press (increase), (decrease) to select when the heat pump
should automatically return to standby mode (1÷24 hours), see Paragraph 5.2.2.
Figure 17: Automatic standby settings.
Automatic standby can only be set when the pump is running, see Paragraph 5.2.4.