Thermal power (heating)
10
[kW] 3.5 5.0 5.0 8.5 10.5
Refrigerant power (cooling) [kW] -
11
4.3 6.8 8.5
Absorbed power
12
[kW] 0.7 1.0 1.0 1.7 2.1
Absorbed current
13
[A] 3.5 5.5 5.5 7.9 9.8
Power voltage
14
[V]
[Hz]
220-240
50
COP
(Coefficient Of Performance)
[ ] 5.0 5.0 4.2 5.0 5.0
ERR (Energy Efficient Ratio) [ ] -
15
3.6 4.0 4.0
Refrigerant - R410A
Refrigerant gas quantity [kg] 0.75 0.85 1.6
Protection grade at water input - IPX4
Number of compressors - 1
Compressor type - Rotary
Heat exchanger - Titanium
Minimum water flow [m
3
/h] 3 3.5 4.0
Hydraulic connections [mm] 50
Number of fans - 1
Absorbed power by fan [W] 70 85 100
Fan RPM [RPM] 830 900 850
Fan air flow direction Orizzontale
Fan air flow [m
3
/h] 1600 2000
Noise [dB(A)] 51 53 54
Dimensions (L/D/H) [mm] 955x305x565 1005x305x610
Net/gross weight [kg] 45/48 51/54 54/57 63/67
10
Variable according to ambient conditions.
11
Modalità di funzionamento non prevista.
12
Variable according to ambient conditions.
13
Variable according to ambient conditions.
14
Single phase alternating current.
15