The RF radius of a configuration can be limited to allow another MXW system to re-use the frequency time-slots. It is best
practice to use the lowest setting that supports the installation. Perform a walk-around test with the transmitters to ensure
that the coverage setting is sufficient.
The RF Power is set from the Preferences tab of the control software. The setting applies to each access point in the
Configuration. Reference the following table for setting the RF Power.
RF Power Levels
Setting Transmitter Power (mW) Coverage Distance from APT Typical Application
Max 80 150 ft Ballroom and auditorium spaces
High 16 100 ft Large meeting spaces and lecture halls
Medium (default) 3 50 ft
Conference, training and multipurpose
rooms
Low 1 25 ft
Small video-conference rooms and
boardrooms