70
Networking
5. Repeat for any additional components.
6. To send updates to the devices, select Apply All to the
Pending Changes field of the Utility page.
7. The computer may temporarily lose connection to the
control software during the updates process. When the
device has been reconfigured, reopen the software using
the Shure Device Discovery application.
Go to Utility > Device Properties to manage the
interfaces of each MXW device on the network.
Manually Assigning Static IP Address
To manually assign IP addresses to the MXW system,
follow these steps:
1. Open the Utility tab.
2. Select Edit to open the device properties window.
3. Select the Manual (Static) IP Mode.
4. Enter the IP settings
5. Select the Add Updates button to queue the saved
settings.
6. Repeat for all additional components
7. Finalize all updates by pressing the Apply All button
from the Utility tab. All devices with pending changes will
update.
Note: The control software may close if settings have been updated for the APT.
8. Change the computer's IP address to match the subnet
of the MXW equipment.
9. Reopen the MXW control interface using the Shure
Device Discovery application.