Press MODE to return to
Settings Page 1
Press MODE to return to Main
Screen
BOD Correction
(Applies to GPS Mode only)
Factory default setting is 15 and
should only be altered during
sea trials
With Main Screen displayed
(Figure 14)
Hold MODE button, Settings
Page 1 will appear (Figure 15)
Press ► to scroll down to BOD
CORRECTION
Press AUTO to edit BOD
CORRECTION
Press ► to increase setting
(more correction)
Press ◄ to decrease setting
(less correction)
Press MODE to return to Settings
Page 1
Press MODE to return to Main
Screen
Reverse Delay
Factory default setting is 15 and
should only be altered during
sea trials
With Main Screen displayed
(Figure 14)
Hold MODE button, Settings Page
1 will appear (Figure 15)
Press ► to scroll down to
REVERSE DELAY
Press AUTO to edit REVERSE
DELAY
Press ► to increase setting
(more delay)
Press ◄ to decrease setting
(less delay)
Press MODE to return to
Settings Page 1
Press MODE to return to
Main Screen
20 of 35
SI-TEX SP-110C
Note: This number increases or
decreases the angle of attack from
a GPS / PC supplied BOD (Bearing
Origin to Destination) when in GPS
mode.
Note: This delay helps reduce
shock load on the rudder drive
train, as it controls the time
between direction changes (eg.
Port to Starboard or Starboard to
Port changes)
Note: Increase this to reduce
rudder hunting.

Table of Contents