SICK Optic-Electronic
Bar Code Scanners
3
Software Configurations
CLV 410 / 412 Test Conditions
O
60
20
O
CLV
20
O
O
60
Test Code
Print Ratio
Code Print Contrast
Scan Frequency
(0.1...0.2 mm Code
Skew
Tilt
Ambient Light
Good Read Rate
Code 39/ITF
3:1
>90%
200...250 Hz
200 Hz)
15°
±10°
<2000 lx
>75%
Test Conditions
Figure 3-15 Reading Distance Test Conditions