EasyManuals Logo

SICK CLV62 Series User Manual

SICK CLV62 Series
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Chapter 4 Operating Instructions
CLV62x Bar Code Scanner
30 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011965/S345/2008-04-16
Product description
4.6.8 Network / interface / IOs
All important interfaces for displaying the reading results are available on the bar code
scanner. Several bar code scanners can be connected to each other via the CAN bus in the
SICK-specific CAN-SENSOR network.
4.6.9 Data interfaces
The following data interfaces are available on the bar code scanner depending on the ver-
sion:
Tab. 4-4: Data interface function
4.6.10 Digital inputs
The external sensor for the object triggering (photoelectric reflex switch) and the incremen-
tal encoder, e.g., can be connected to the digital switching inputs.
Important The connection "Sensor 2" is only available on the standard version of the bar code scanner.
For the Ethernet version of the bar code scanner, this input is only available with the con-
nection module CDB620/CDM420 in combination with the parameter memory module
CMC600.
Note
The network parameters can be configured using the SOPAS-ET configuration software:
P
ROJECT TREE, CLV62X, PARAMETER, NETWORK / INTERFACE / IOS, tab pages NETWORK OPTIONS
Data interface Function
Host interface
(RS-232 or RS-422/485
and Ethernet host port)
Preparation of the reading result for further processing by the host
processor
Auxiliary interface (RS-232
and Ethernet aux port)
Reading diagnosis or host interface monitoring
CAN Networking several bar code scanners
Note
The data interfaces can be configured using the SOPAS-ET configuration software:
P
ROJECT TREE, CLV62X, PARAMETER, NETWORK / INTERFACE / IOS, SERIAL
PROJECT TREE, CLV62X, PARAMETER, NETWORK / INTERFACE / IOS, ETHERNET
PROJECT TREE, CLV62X, PARAMETER, NETWORK / INTERFACE / IOS, CAN
Note
The digital inputs can be configured using the SOPAS-ET configuration software:
P
ROJECT TREE, CLV62X, PARAMETER, NETWORK / INTERFACE / IOS, DIGITAL INPUTS

Table of Contents

Other manuals for SICK CLV62 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV62 Series and is the answer not in the manual?

SICK CLV62 Series Specifications

General IconGeneral
BrandSICK
ModelCLV62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals