EasyManua.ls Logo

SICK DUSTHUNTER SB30

SICK DUSTHUNTER SB30
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
53
8026957/AE00/V1-0/2021-08| SICK OPERATING INSTRUCTIONS | DUSTHUNTER SB30
Subject to change without notice
MAINTENANCE 6
6.2 Maintenance on the sender/receiver unit
Clean the outside of the sender/receiver unit in regular intervals. Remove deposits with
water or mechanically using suitable auxiliary means.
Work to be performed
Loosen CAMLOCK clips (1) of the sender/receiver unit and swivel electronics unit (2) to
the side.
Check mounting flange (5) and purge air connections (see “Sender/receiver unit DHSB-
T”, page 15) for contamination and clean when necessary.
Carefully clean sender optics (3) and receiver optics (4) with an optics cloth or cotton
swabs.
Reassemble the sender/receiver unit again.
Resume Measuring mode.
Fig. 30: Cleaning the optical interfaces
NOTE:
Do not damage any device parts during maintenance work.
Do not interrupt the purge air supply.
WARNING: Danger from exhaust gas
The sender/receiver unit must be opened for cleaning. It is possible that gas escapes in
plants with overpressure in the duct.
Take suitable protection measures or open the sender/receiver unit only
when the plant is at a standstill.

CAMLOCK clips
Receiver optics
Electronics unit
Mounting flange
Sender optics

Table of Contents

Other manuals for SICK DUSTHUNTER SB30