Installing a SensorApp on a device.
Reading and changing the device’s IP address.
Starting, stopping or deleting an installed SensorApp.
Installing firmware updates.
Download SICK AppManager from www.sick.com/SICK_AppManager. To install SICK
AppManager on the computer, open the installation (.exe) file and follow the instruc‐
tions on the screen.
SICK AppStudio
The SICK AppStudio development environment is used to program the device and to
perform diagnostics in case of faults.
The use of SICK AppStudio requires a valid license. A one-year license (art no
1610199) is available from www.sick.com/SICK_AppStudio. After purchasing the
license, download the SICK AppStudio software from the SICK Support Portal, support‐
portal.sick.com.
After downloading SICK AppStudio, follow the on-screen instructions to complete the
installation.
8.3
Network communication settings
To connect to the device from a computer, make sure that the network communication
settings are correctly set up:
The device must be connected to the computer via Ethernet (P3) or USB.
The computer must be on the same network as the device.
The computer must not use the same IP address as the device.
Default IP addresses:
Ethernet (P3): 192.168.0.1
USB: 169.254.0.1
Editing the device's IP address
To change the device's IP address using SICK AppManager:
1. Open SICK AppManager.
All connected devices on the network are listed on the Device search tab.
2. Select the correct device in the list.
3. Click Edit IP address.
4. Enter the new IP address for the device.
8.4
Default SensorApp: Nova 2D
The Nova 2D SensorApp with a pre-activated Quality Inspection license is pre-installed
on the device and is also available for download from SICK AppPool. The Nova 2D
SensorApp uses vision-based quality inspection to ensure that produced items have the
exact qualities required regarding presence and measurements of details.
Opening the user interface
Nova 2D is configured through a web-based graphical user interface. To open the user
interface from a web browser:
1. Open a web browser window.
2. Type the IP address of the device. The default IP address is 192.168.0.1.
8 COMMISSIONING
42
O P E R A T I N G I N S T R U C T I O N S | Inspector83x 8029044/1MYO/2024-04 | SICK
Subject to change without notice