12 Technical data
NOTE
T
he relevant online product page for your product, including technical data, dimensional
drawing, and connection diagrams, can be downloaded, saved, and printed from the
Internet.
The product page can be accessed via the SICK ProductID: pid.sick.com/{P/N}/{S/N}
{P/N} corresponds to the part number of the product, see type label.
{S/N} corresponds to the serial number of the product, see type label (if indicated).
Please note: This documentation may contain further technical data.
12.1 Features
Inspector83x
Typical applica‐
t
ion
Indoor area
Task Quality Inspection
Position determination
Measuring 2D
Code reading
1)
Technology 2D snapshot, image analysis, Deep Learning
Product category Programmable, configurable
SensorApp Nova 2D SensorApp included, with pre-activated Quality Inspection License
or Int
elligent Inspection License.
2)
Based on the SICK Nova SensorApp foundation, which allows functional
extensions via tool plug-ins and custom development.
Toolkit SICK algorithm API
H
ALCON
Sensor CMOS matrix sensor, grayscale values
D
epends on type, see "Type code", page 15.
Shutter technol‐
o
gy
Global shutter
Optical focus Adjustable focus (manually)
Working distance Typically 200mm…2,500mm
3)
Sensor resolution Depends on type, see "T
ype code", page 15.
Integrated lllumi‐
na
tion
Order separately as an accessory, e.g. variant of the VI55I illumination unit
Variants of the VI55I illumination unit with 16 LEDs:
Visible white light, medium, aperture angle: 31°
Visible white light, wide, aperture angle: 47°
LED risk group of
t
he illumination
unit (visible white
light variant)
Risk group 1 (low risk) according to IEC62471-1: 2006-07/EN62471-1:
2008-09
Radiance:
L
B
4)
: <10 x 10
3
W/(m
2
sr) within 100seconds; at a distance ≥200mm
L
R
5)
: <2.5 x 10
6
W/(m
2
sr) within 10seconds; at a distance ≥200mm
Lens C-mount
Or
der separately as an accessory