If you cannot connect to the device, verify that the network adapter associated with the
USB interface has an IP address on the subnet 169.254.0.x. If this IP address is wrong
or missing, make sure that the relevant network adapter is configured to obtain an IP
address automatically.
NOTE
The network adapter associated with the USB interface is different from the network
adapter associated with the Ethernet interface.
NOTE
Both the computer and the device must be set up for communication on the same
network.
4.5 User interface
Opening the user interface
1. Open a web browser window.
2. Type the IP address of the device. The default IP address is 192.168.0.1.
NOTE
If you do not remember the device IP address, SICK AppManager will help you find it.
4 GETTING STARTED
26
O P E R A T I N G I N S T R U C T I O N S | Inspector83x 8029044/1MYO/2024-04 | SICK
Subject to change without notice