Functions
Function Description
Cloning Save currently valid save parameter set on an external storage
medium. The externally stored parameter set is also updated auto‐
matically each time the parameterization is permanently saved.
The cloning function provides the means, for example in the event
of a device fault, for manual transmission of the parameter set to
an exchange unit of the same type.
Other functions are available upon request.
Further topics
•
Inserting and removing memory card
8.7.1 Inserting and removing memory card
Important information
NOTICE
Loss of configuration data
Do not remove the memory card or switch off the supply voltage while the parameter
set is being saved. Otherwise all parameters not yet saved permanently will be lost.
Prerequisites
•
The supply voltage for the product is switched off.
•
If the cover is open, the product does not fulfill any specified enclosure rating. Only
briefly open the cover. Protect the product against moisture and dust during this
time.
Approach
Inserting the memory card
1. Open the rubber cover.
2. Making sure it is in the correct position, insert the memory card into the slot until
it locks into place. To do so, align the product as per the card icon.
3. Close the cover again. Make sure that the cover is flush with product.
4. Switch on the supply voltage for the product.
Removing memory card
1. Push the memory card into the slot until it is released.
2. Remove the memory card.
3. Close the cover again. Make sure that the cover is completely flush with the
product when closed.
4. Switch on the supply voltage for the product.
COMMISSIONING 8
8029044/1MYO/2024-04 | SICK O P E R A T I N G I N S T R U C T I O N S | Inspector83x
45
Subject to change without notice