WARNING
Risk of injury and damage caused by potential equalization currents!
Improper grounding can lead to dangerous equipotential bonding currents, which may
in turn lead to dangerous voltages on metallic surfaces, such as the housing. Electrical
voltage can cause severe injury or death.
Work on electrical systems must only be performed by qualified electricians.
Follow the notes in the operating instructions.
Install the grounding for the product and the system in accordance with national
and regional regulations.
2.8 Warning signs on the device
LMS4x2x
Figure 1: LMS4x2x – Warning signs on the device
1
Avoid exposure – Laser radiation is emitted from this aperture.
Laser output aperture corresponds to the front screen at the height of the position shown.
2
Caution – Laser radiation when opened. Do not stare into beam.
3
Laser radiation – Do not stare into beam. Class 2 laser product
Average radiation output: 13.5 mW
Maximum radiation output: 27 mW
Wavelength: 660 nm
IEC 60825-1:2014
Complies with 21 CFR 1040.10 and 1040.11 except for tolerances according to Laser
Notice No. 50 of June 24, 2007.
4
Warning symbol: Laser radiation
5
Do not remove – Hazardous laser radiation and risk of personal injury if the laser protec‐
tion hood is removed. Limit values of laser class 2 are exceeded.
2 SAFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | LMS4400/LMS4500 8023202/16S6/2020-01-24 | SICK