Features
Version Short range
Application Indoor
Reading window/laser out‐
put aperture
On the front
Light source/laser diode Visible light
(wavelength 660 nm; LMS4x11: max. output power 20 mW, aver‐
age power 10 mW; LMS4x21: max. output power 27 mW, average
power 13.5 mW)
Laser class 2 (IEC 60825-1:2014&2007)
Spot size/laser spread 4 x 3 mm, typical (front screen)
2.5 x 2 mm (3 m distance)
Aperture angle 70°
Scan frequency 600 Hz
Angular resolution 1/12° (0.0833°)
Operating range 0,7 m ... 3 m
Scanning range 3 m (LMS4x21: 2 % remission; LMS4x11: 3.5 % remission)
3 m (10 % remission)
Number of devices for
motor synchronization
Virtually unlimited, length of sync cable max. 20 m
10 TECHNICAL DATA