Vibration resistance Vibration, sinusoidal (EN 60068-2-6:2007):
10 Hz … 100 Hz, 0.35 mm, 5 g, 20 cycles
Shock resistance Non-repetitive shock (EN 60068-2-27:2008):
15 g, 11 ms, 6 shocks per axis
10 g, 16 ms, 1,000 shocks per axis
Ambient operating temper‐
ature
-10 °C ... +50 °C (initialization phase: 0 °C ... +50 °C)
Storage temperature -20 °C ... +70 °C
Permissible relative
humidity
Max. 90% (non-condensing)
Ambient light immunity 2000 lx
1
1
Illuminance from measurement object; Value for unrestricted measurement performance; Maximum
value about 60000 lx
10 TECHNICAL DATA
50
O P E R A T I N G I N S T R U C T I O N S | LMS4400/LMS4500 8023202/16S6/2020-01-24 | SICK
Subject to change without notice