7.3.1.1 Identification
7.3.1.1.1 Serial number
Overview
Name SerialNumber
Index 3
Data type FlexString (length ≤ 24)
User group Run
Access rights Read
Description
T
he variable only offers read access.
The variable contains 2 serial numbers:
Serial number (device without system plug)
Serial number (system plug)
The value is output as a string (ISO 8859-15).
The serial numbers are separated by a slash (0x2F).
Communication example
T
able 22: SerialNumber: Variable recall
CoLa2 telegram (HEX) ISO 8859-15
02 02 02 02 00 00 00 0c 00 00 5a 84 91 dd 00 02
52 49 03 00
..........Z.....
RI..
Table 23: SerialNumber: Sensor response (example)
CoLa2 telegram (HEX) ISO 8859-15
02 02 02 02 00 00 00 1f 00 00 5a 84 91 dd 00 02
52 41 03 00 11 00 31 36 34 31 39 30 38 37 2f 31
36 34 30 31 36 33 38
..........Z.....
RA....16419087/1
6401638
7.3.1.1.2 Firmware version
Overview
Name FirmwareVersion
Index 4
Data type FlexString (length ≤ 24)
User group Run
Access rights Read
Description
T
he variable only offers read access.
The variable contains the firmware version of the device.
The value is output as a string (ISO 8859-15).
7 ANNE
X
38
T E C H N I C A L I N F O R M A T I O N | microScan3, outdoorScan3 8022708/2019-04-15 | SICK
Subject to change without notice