100
6 WIRING
6.4 External Wiring Example
Wiring a transmissive photoelectric switch and an universal output expansion module
The following shows an example of the program 3.2 with a restart interlock and EDM.
(1) Switch
I0
I1
I2
I3
X0
X1
X2
+
FG
Q0
Q1
Q2
Q3
T0
T1
XS0
-
FG
FX5-SF-MU4T5
FUNCTION
SICK
UE10-30S
B1
B2
B3
B4
Y1 13 23 33 41
Y2 14 24 34 42
L21SL21E
L21E
L21E
L21S
L21S
+24V +24V
+24V +24V
+24V
+24V
0V
Q
0V
TE
0V
Q
0V
TE
0V
TE
0V
Q
+24V
0V
2) PELV
(1)