2 SPECIFICATIONS
2.5 Safety Output Derating Curve
Safety inputs of an FX5-SF-8DI4
Test outputs of an FX5-SF-8DI4
*1 A cross-circuit detection is performed only in the module.
Response time of FX5-SF-8DI4
2.5 Safety Output Derating Curve
The following figure shows the derating curve for safety outputs (Q0 to Q3) of an FX5-SF-MU4T5.
Item Specification
Number of inputs 8 points
Input voltage (ON) 13 VDC to 30 VDC
Input voltage (OFF) -5 VDC to 5 VDC
Input current (ON) 3 mA (2.4 mA to 3.8 mA)
Input current (OFF) -2.5 mA to 2.1 mA
Indication of input operation LED lights when an input is ON.
Minimum switch-off time Program 1, 2, 3, 4, 5, and 8 24 ms
Program 6 and 7 4 ms
Synchronous time monitoring Program 3 and 5 1500 ms
Power-up time 70 ms
Item Specification
Number of outputs 8 points
Output method Source output, short-circuit protection, cross-circuit detection
*1
Output voltage 16 VDC to 30 VDC
Output current 30 mA
Test cycle 40 ms
Item Specification
Response time Program 1, 2, 3, 4, 5, and 8 33 ms
Program 6 and 7 13 ms
(1) Load current (A)
(2) Ambient temperature ()